Coax Table

and other transmission lines
#  (not in
impedance 
attenuation per 100'
  dB
velocity 
max voltage RMS kV
 strict order)
  ohms Z
@ 50MHz 
@ 1GHz 
(material)
RG6U 
75 
1.5 dB 
11 dB 
78% (foam) 
2.7  kV
RG6catv
75

6.5

0.35
RG8U 
52 
1.2 

66 (polyethlene) 
5   kV
RG8U 
50 
1.1 
 
78 (foam) 
0.6
RG8X 
50 
 
13.5 
 
2.5
RG11U 
75 
1.3 

66 (poly) 
5
RG11U 
75 
1.0 
 
78 (foam) 
0.6
RG55B/U 
53.5 
 
16.5 
 
1.9
RG58U 
53 
3.1 
20 
66 (poly) 
1.9  kV
RG58U 
50 
3.2 
 
78 (foam) 
0.2  kV
RG59U 
73 
2.4 
11.5 
66 (poly) 
2.3
RG62U 
93 
1.9 
8.5 
84 (air & poly) 
0.7  kV
RG59U 
75 
2.1 
 
78 (foam) 
0.3  kV
RG71U 
93 
1.9 
8.5 
84 (air & poly) 
0.7
RG108A/U 
78 
 
26.2 
 
1.0
RG122U 
50 
4.5 
29.2 
66 (poly) 
1.9
RG140U 
75 
 
13 
 
2.3
RG141U 
50 
2.1 
13 
69 (teflon) 
1.9
RG142U 
50 
2.7 
13 
69 (teflon) 1.9
RG178U 
50 
10.5 
45 
69 (teflon) 1.0
RG179U 
75 
8.5 
25 
69 (teflon) 1.2
179DT 
75 

20.7 
77 (Foam HDPE) .
RG180U 
95 
4.6 
16.5 
69 (teflon) 1.5
RG187U 
75 
8.5 
25 
69 (teflon) 1.2
RG188U 
50 
9.6 
30 
69  teflon) 1.2
RG196U 
50 
10.5 
45 
69  (teflon) 1.2
RG303U 
50 
2.1 
13 
69  (teflon) 1.9
RG302U 
75 
 
13 
 
2.3
RG316U 
50 
9.4 
30 
69  (teflon) 1.2
RG393U 
50 
 
7.5 
 
5
RG400U 
50 
 
13 
 
1.9
RG401U 
50 
 
7.5 
(semi rigid)
3
RG402U 
50 
 
13 
(semi rigid) 2.5
RG405U 
50 
 
22 
(semi rigid) 2
RG174U 
50 
6.6 
31 
66 (poly) 
1.5
RG210U 
93 
 
3.1 
 
0.75
RG213U 
50 
1.6 

66 (poly)  5
RG214U 
50 
1.6 

66 (poly)  5
RG216/U
75

9.0

5
RG217U 
50 
 
5.8 
 
7
RG218U 
50 
 
3.8 
 
11 kV
RG219U 
50 
 
3.8 
 
11
RG223U 
50 
3.1 
16.5 
66 (poly)  1.9
RG225U 
50 
 
7.5 
 
5
RG9U 
51 
1.6 
 
66 (poly)  5
ethernet 
(thick net)
50 
1.2 
 
78 (foam) 
0.6
22B/U 
95
(twisted pair)
2.1 
 
66 (poly) 

twin lead 
300 
0.8 --worse when wet!
  80 (poly) 

8281 
75 
 
9.2 
 
2.9
9913 
50 
 
4.5 
 
0.6
CAT 5e
(per twisted pair) 
100 
4.4
11@250MHz 
 
68 
0.03KV, 360mA,
10W RF max
9914 
50 
 

 
0.6
8218 
75 
 
20 
 
0.6
The attenuation curves generally follow a straight line when drawn on log-log graph paper. The slope is such that a coax with 2dB at 50Mhz will be 0.8 at 10Mhz. Most coaxes have about the same slope. What causes this attenuation is mostly the "skin effect" on the center conductor. So  one need only look at the same freq when comparing attenuations when selecting which coax you're gonna use from under the shack table (not strictly true, but close enough for "goverment" work! :-) ). Voltage ratings: note that foam dielectric cannot take as much voltage as solid dielectric.